| PUMPS | ![]() |
![]() |
![]() |
![]() |
| type |
(UP)
PUA-A
|
GFB
|
PME/GME
|
PMM
|
| drive |
2
|
11
|
6
|
2;3
|
| number of outlets |
1
|
1
|
2
or 4
|
1÷
6
|
| maximum operating pressure |
-
|
32
(bars)
|
25
(bars)
|
oil
15; grease 60 (bars)
|
| delivery volume per outlet |
1
(ccm/rev)
|
60;
120; 180 (ccm/stroke)
|
0,43
(ccm/stroke)
|
0,02-0,06
(ccm/stroke)
|
| reservoir
size L, level monitoring N |
-
|
5;10;
(L); N
|
5;10;(L);
N
|
0,7;1,5;3
(L);N
|
| suitable
for oil O, grease F |
O
|
O
|
O
|
F
O
|
| suitable for lubricating system type |
U
|
UPO
|
MPO
|
MPO
|
| individual brochure/ leaflet |
353.000
|
372.000
|
105.000/100
|
103.000
|
| PUMPS | ![]() |
![]() |
![]() |
![]() |
| type |
GMM
|
PMS
|
GMS
|
(R)PMR
|
| drive |
11
|
3
|
11
|
1;
2; 3; 6; 8
|
| number of outlets |
1÷6
|
1÷6
|
1÷6
|
1÷20
|
| maximum operating pressure |
oil
15; grease 60 (bars)
|
oil
15; grease 60 (bars)
|
oil
15; grease 60 (bars)
|
250
(bars)
|
| delivery volume per outlet |
0,02-0,06
(ccm/stroke)
|
0,02÷15
(ccm/h)
|
0,18÷36
(ccm/h)
|
0,16-0,22
(ccm/stroke)
|
| reservoir
size L, level monitoring N |
0,7;1,5;3
(L);N
|
0,7;1,5;3
(L);N
|
0,7;1,5;3
(L);N
|
1,5
& 5 (L);N
|
| suitable
for oil O, grease F |
F
O
|
F
O
|
F
O
|
O
|
| suitable for lubricating system type |
MPO
|
MPO
|
MPO
|
MPO
|
| individual brochure/ leaflet |
103.000
|
103.350
|
103.350
|
109.000
|
| PUMPS | ![]() |
![]() |
![]() |
![]() |
| type |
(R)GMR
|
(FS)PMF
|
(FS)GMF
|
(FKPW)PMW
|
| drive |
11
|
1;
2; 3; 6; 8; 9
|
11
|
7
|
| number of outlets |
1÷20
|
1÷26
|
1÷26
|
1÷5
|
| maximum operating pressure |
250
(bars)
|
350
(bars)
|
350
(bars)
|
125
(bars)
|
| delivery volume per outlet |
0,16-0,22
(ccm/stroke)
|
0,08
& 0,15
(ccm/stroke)
|
0,08
& 0,15
(ccm/stroke)
|
0,08
& 0,15
(ccm/stroke)
|
| reservoir
size L, level monitoring N |
1,5
& 5 (L);N
|
2;4;5;7;10;25;30;60
(L);N
|
2;4;5;7;10;25;30;60
(L);N
|
2;4;5;7;10;25;30;60
(L);N
|
| suitable
for oil O, grease F |
O
|
F
O
|
F
O
|
FO
|
| suitable for lubricating system type |
MPO
|
MPO
|
MPO
|
MPOS
|
| individual brochure/ leaflet |
109.000
|
110.000
|
110.000
|
114.000
|
| PUMPS | ![]() |
![]() |
![]() |
![]() |
| type |
GMZ-A
|
PMX-B,C
|
PEH
|
PEK
|
| drive |
11
|
9
|
1;
8
|
6
|
| number of outlets |
1÷10
|
2
|
1
|
1
|
| maximum operating pressure |
350
(bars)
|
50
|
60
(bars)
|
45
(bars)
|
| delivery volume per outlet |
0,08
& 0,15
(ccm/stroke)
|
1,3
(ccm/stroke)
|
max
10 (ccm/stroke)
|
max
10 (ccm/stroke)
|
| reservoir
size L, level monitoring N |
(drum
200 (L))
|
0,7
(L);N
|
1
(L);N
|
1,5
(L);N
|
| suitable
for oil O, grease F |
F
|
O
|
O
|
O
|
| suitable for lubricating system type |
MPS
|
MPO
|
EP
|
EPO
|
| individual brochure/ leaflet |
111.350
|
106.120
|
151.000
|
157.000
|
| PUMPS | ![]() |
![]() |
![]() |
![]() |
| type |
(PA
15 M1)PEB-A
|
(ZMVE)GEZ-A
|
GEB
|
PZH-A,B
|
| drive |
10
|
6;
8;11
|
11
|
1
|
| number of outlets |
1
|
1
|
1
|
2
|
| maximum operating pressure |
25
(bars)
|
45
(bars)
|
32
(bars)
|
150
(bars)
|
| delivery volume per outlet |
1,5
(ccm/stroke)
|
0,25
(ccm/stroke)
|
250
(ccm/stroke)
|
0,8
(ccm/stroke)
|
| reservoir
size L, level monitoring N |
2
(L);N
|
-
|
5;
10;
(L);N
|
1,2
(L)
|
| suitable
for oil O, grease F |
O
|
O
|
O
|
F
O
|
| suitable for lubricating system type |
EPO
|
UEZPO
|
EO
|
Z
|
| individual brochure/ leaflet |
155.310
|
158.110
|
179.000
|
252.700
|
| PUMPS | ![]() |
![]() |
![]() |
![]() |
| type |
GZX-B
|
GZX-C
|
GZB-A,B,C
|
GZC-A
|
| drive |
11
|
11
|
11
|
11
|
| number of outlets |
2
|
2
|
2
|
4
& 8
|
| maximum operating pressure |
32
(bars)
|
32
(bars)
|
60
(bars)
|
150
(bars)
|
| delivery volume per outlet |
1,2
(ccm/stroke)
|
1,2
(ccm/stroke)
|
2
(ccm/min)
|
8,4
& 16,8 (ccm/stroke)
|
| reservoir
size L, level monitoring N |
1,5
(L);N
|
-
|
1,5
(L)
|
5;7;10
(L);N
|
| suitable
for oil O, grease F |
O
|
O
|
F
|
F
|
| suitable for lubricating system type |
Z
(P) O
|
ZO
(P)
|
Z
(P)
|
Z
(P)
|
| individual brochure/ leaflet |
252.200
|
252.300
|
252.100
|
252.500
|
| PUMPS | ![]() |
![]() |
| type |
GZD
|
GOB-A,B
|
| drive |
11
|
10
|
| number of outlets |
2
|
1
& 2
|
| maximum operating pressure |
oil
200, grease 400 (bars)
|
6
(bars)
|
| delivery volume per outlet |
100
(ccm/min)
|
30
(ccm/stroke)
|
| reservoir
size L, level monitoring N |
50
(L);N
|
0,7
(L);N
|
| suitable
for oil O, grease F |
F
O
|
O
|
| suitable for lubricating system type |
Z
(P)
|
O
|
| individual brochure/ leaflet |
252.600
|
165.320/330
|
| DISTRIBUTORS | ![]() |
![]() |
![]() |
![]() |
| type |
VZE
|
VPA-B
|
VPA-C
|
VPA-D
|
| number of outlets |
2÷8
|
6÷20
|
6÷20
|
6÷20
|
| volume |
0,2÷1,5
(ccm)
|
0,09;
0,2 (cm3)
|
0,1÷0,9
(cm3)
|
0,9÷3,7(cm3)
|
| visual monitoring |
yes
|
on
request
|
on
request
|
on
request
|
| elect. volume monitoring |
on
request
|
on
request
|
on
request
|
on
request
|
| suitable
for oil O, grease F |
F
O
|
F
O
|
F
O
|
F
O
|
| suitable for lubricating system type |
Z
|
P
|
P
|
P
|
| maximum operating pressure |
O=200;
F=400 (bars)
|
150
(bars)
|
150
(bars)
|
150
(bars)
|
| individual brochure/ leaflet |
259.980
|
205.000
|
205.000
|
205.600
|
| DISTRIBUTORS | ![]() |
![]() |
![]() |
![]() |
| type |
(VEK/VEM)
VPS-K/VPS-M
|
VPE-K,
M
|
EV/EVK
|
VOE-A
|
| number of outlets |
2÷30
|
2÷30
|
2
& 4
|
2÷10
|
| volume |
0,1÷1,0
(cm3)
|
0,1÷1,0
(cm3)
|
0,16÷0,6
(cm3)
|
0,011÷0,23
(cm3)
|
| visual monitoring |
on
request
|
on
request
|
-
|
-
|
| elect. volume monitoring |
on
request
|
on
request
|
on
request
|
-
|
| suitable
for oil O, grease F |
F
O
|
F
O
|
F
O
|
O
|
| suitable for lubricating system type |
P
|
P
|
P
|
O
|
| maximum operating pressure |
150
(bars)
|
150
(bars)
|
50
(bars)
|
16÷45
(bars)
|
| individual brochure/ leaflet |
206.100
|
206.400
|
209.000
|
165.060
|
| DISTRIBUTORS | ![]() |
![]() |
![]() |
![]() |
| type |
VOZ-A
|
VOM-A
|
VOP-B
|
flow
control unit
VUA-A |
| number of outlets |
2÷12
|
2÷10
|
6÷10
|
1÷6
|
| volume |
0,03÷0,14
(cm3)
|
according
to multi-line pumps
|
0,1÷0,2
(cm3)
|
0,1÷5
(dm3/min)
|
| visual monitoring |
-
|
-
|
on
request
|
-
|
| elect. volume monitoring |
-
|
-
|
on
request
|
on
request
|
| suitable
for oil O, grease F |
O
|
O
|
O
|
O
|
| suitable for lubricating system type |
O
|
O
|
O
|
U
|
| maximum operating pressure |
25÷100
(bars)
|
min
10 (bars)
|
150
(bars)
|
100
(bars)
|
| individual brochure/ leaflet |
165.270
|
165.280
|
165.290
|
357.100
|
| SPRAY EQUIPMENT | ![]() |
![]() |
![]() |
| type |
|
|
SBB-A
|
| Destination |
flat
spray nozzle
|
circular
spray nozzle
|
straight
nozzle
|
| note |
-
|
-
|
-
|
| suitable for oil O, grease F |
F
|
O
F
|
O
F
|
| individual brochure/ leaflet |
330.135
|
330.110
|
330.180
|
| SPRAY EQUIPMENT |
![]() |
![]() |
| type |
SBB-B
|
SBD-A
|
| Destination |
agle-type
nozzle
|
spraying
unit
|
| note |
-
|
spray
volume/ stroke adjustable to (ccm) max
|
| suitable for oil O, grease F |
O
F
|
F
|
| individual brochure/ leaflet |
330.180
|
330.400
|
| CONTROL & MONITORING UNITS |
![]() |
![]() |
![]() |
![]() |
| type |
EUS-A
|
EUF-A
|
ETL-B
|
EZB-A
|
| destignation |
monitoring
unit
|
monitoring
unit 1
|
control
unit 1
|
control
electronic
|
| note |
pulse
sequence monitoring- monitoring time infinitely variable
|
pulse
addition-pulses adjustable by means of decade switch from 2-198 pulses
|
load-dependent
on pulse-dependant off. monitoring of operative period
|
operative
period 2 seconds inoperative period 4-300 sec.
|
| individual brochure/leaflet |
460.755
|
460.790
|
453.265
|
467.005
|
| CONTROL
& MONITORING UNITS |
![]() |
![]() |
![]() |
| type |
EZD/EZE
|
EVA-A
|
simple
|
| destignation |
control
electo-mechanical timer
|
control
unit
|
control
and monitoring unit
|
| note |
operative
period and inoperative period 0.1 sec. to 60hrs. with storage
|
switching
amplifier for 4 spraying units max.
|
for
all lubricating systems
|
| individual brochure/leaflet |
467...
|
463.460
|
460...
|